$12.00
$12.00
MODEL | 05V60W | 12V60W | 24V60W | ||||||||
DC VOLTAGE | 5V | 12V | 24V | ||||||||
RATED CURRENT | 12A | 5A | 2.5A | ||||||||
CURRENT RANGE | 0~12A | 0~5A | 0~2.5A | ||||||||
RATED POWER | 60W | 60W | 60W | ||||||||
NOTE.2 RIPPLE & NOISE (max.) | 150mV | 150mV | 150mV | ||||||||
NOTE.3 VOLTAGE TOLERANCE | ±10% | ±4% | ±2% | ||||||||
SETUP, RISE TIME | 80ms/220VAC | ||||||||||
HOLD UP TIME (Typ.) | 60ms/220VAC | ||||||||||
VOLTAGE RANGE | 170~ 250VAC | ||||||||||
FREQUENCY RANGE | 50~ 60Hz | ||||||||||
POWER FACTOR (Typ.) | PF>0.6/220VAC | ||||||||||
EFFICIENCY (Typ.) | 77% | 80% | 81% | ||||||||
AC CURRENT (Typ.) | 0.57A/220VAC | ||||||||||
INRUSH CURRENT (Typ.) | COLDSTART40A/220VAC | ||||||||||
Short circuit | Protection type : recovers automatically after fault condition is removed | ||||||||||
Overload | overload protected @ 145-160% above peak rating | ||||||||||
Over temperature | Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
WORKING TEMP. | -30 ~ +50(Refer to output load derating curve) | ||||||||||
WORKING HUMIDITY | 20 ~ 99% RH non-condensing(Waterproof) | ||||||||||
STORAGETEMP.,HUMIDITY | -40 ~ +80, 10 ~ 99% RH | ||||||||||
SAFETY STANDARDS | CE Mark(LVD) , IP67 | ||||||||||
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-GND:1.5KVAC | ||||||||||
EMC TestStandards | EN55015:2006; EN61547:1995+A1:2000; EN61000-3-2:2006; EN61000-3-3:1995+A2:2005; EN61347-1:2001; EN61347-2-13:2006 | ||||||||||
1. All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 10uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
inquiry
$35.00
$35.00
$28.00
$19.00
$20.00
$20.00
$1.00
$7.95
$0.50
$20.00
$35.00
30W/60W/150W/250W/300W LED Power Supply
Response Rate: High
Avg Response Time: 24–48 h
Business Type:Manufacturer/Factory