Product Name: 35kv 110mva Three Phase Arc Furnace Transformer Model NO.: HSPPZ-110000/35-1-0.864-0.66 Brand: Eacher Shape of Core: Kou Type Frequency Characteristics: Power Frequency Usage: Arc Furnace Transformer Certification: ISO9001-2000, ISO9001 Winding Type: Two-winding Transformer Cooling Method: Oil-immersed Type Transformer Core: Core-type Transformer Phase: Three Application: Arc Furnace Transformer Service Condition: Indoor Tap Changer: Oltc Cooling Type: Ofwf Core Structure: Toroidal High Voltage Range: 6-11kv Iron Core: Silicon Sheet Loss: Low Loss Winding Material: Copper Bushing: Porcelain Colour: Customized Switch: Mr Vacuum on Load Tap Changer Frequency: 50Hz/60Hz Trademark: EACHER Transport Package: Sea Worthy Packing Specification: CE, ISO, IEC, GB, ANSI Origin: Jiangshan City, Zhejiang Province, China Product Description Product Description35kv 110mva arc furnace transformer1. Top three in China, advanced performance2. CE, IEC, ANSI3. ISO, OHSAS4. Up to 150MVAApplication:Arc furnaces are used in steel industry for smelting scrap iron and for refining steel. Other application areas are :1) Smelting glass and ceramics2) Manufacturing or refining many other materials etc. ferrochromium, ferromanganese, different abrasive materials (oxides and nitrides), semiconducting base materials, nanopowders etc.3) Electric arc furnace (EAF) transformers are required for many different furnace processes and applications . they are built for :a , Steel furnaces, mainly long arcb, Landle furnacesc, ferro-alloy furnace and similar with short or submerged ared,Smelting of other materialsFeatures:1) Low loss2) Low noise3) High efficiency4) Low partial discharge5) Strong mechanical strength and short-circuit withstand ability .6) Operation reliability7) Easy maintenance8) Pretty outline and compact structure9) 100% guaranteed no leakageBrief specification:1) Voltage class: 6~110 KV2) Capacity : 630 KVA to 120,000 KVA3) Short-circuit impedance : 4.5~21%4) Losses : No-load losses is fully comply with IEC standard requirements35kV Furnace Transformer Technical ParametersTypeRated power(kVA)ConnectionsymbolPrimary voltage(kV)Secondary Voltage(v)Regulation voltage stepType of tapingshort-circuit impedance(%)No-load lossOn-load lossHSSPZ-1500/351500Yd1135290~15710On-load5.52.623HSSP-3200/353200D-Y,d0-1135240~1384No-load75.341.1HSSPK-3200/353200D-Y,d0-1135240~1385No-load18.655.391.1HJSSP-5000/355000Yd1135212~1555No-load7.59.355HJSSP-5500/355500Yd1135240~1306No-load79.152.5HJSSP-7000/357000Yd1135240~1408No-load6.59.477HJSSPZ-9000/359000Yd1135239~1639On-load8.511.697HSSP-9000/359000Yd1135320~1808No-load611116HJSSPZ-10000/3510000Yd1135260~1889On-load8.517.2187HSSPZ-10000/3510000Yd1135300~16013On-load6.51297HSSPZ-12500/3512500Yd1135250~1509On-load919.7134HSSP-12500/3512500Yd1135340~19511No-load813.9154HSSP-15000/3515000D-Y,d0-1135353~1608No-load820107HSSPZ-16000/3516000Yd1135375~20015On-load716.416.1HJSSPZ-16000/3516000Yd1135310~19013On-load719.2195.6HSSPZ-20000/3520000Yd1135400~27013On-load720.7207.7HJSSPZ-20000/3520000Dd035320~17011On-load6.530.430.4HSSPZ-25000/3525000Yd1135509~30213On-load7.528.528.5Transformer accessoriesCertificationsCertificates owned by shenda:100MVA/220kv power transformer short circuit test report-issued by CESI Italy&CTQC China120MVA/33KV oil EAF transformer50MVA/69KV oil power transformer10MVA/33kv dry-type transformerType test report-issued by KEMA Netherlands63MVA/110KV Power transformer short circuit test report-issued by CTQC China12.5MVA/22KV Rectifier transformer routine test-issued by V-Check koreaISO 9001&ISO14001&OHSAS 18001CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTORTransformer CharacteristicsWinding .The winding must be especially protected - both against high electrical stress due toexternal over voltages and against mechanical overloads by short circuits. They are made of copper or aluminum. Low-voltage windings are made of strip or flat wire whilehigh voltage windings are manufactured from round or profile wire. ("diamond-dotted paper") bonds the winding into a compact blockwhile drying and increases the short-circuit capacity additionally.Magnetic Core lamination.The three-limb iron core is made of oblique cut Grain-oriented, seven-step silicon steel lamination insulated on both sides,guaranteeing low losses and low noise. These values are even improved by laser treatment. It is protected on the surface with aflash-proof varnish in order to prevent the sheet from corrosion and to reduce the noise.Oil tank.Whether during transport or operation -the tank must be absolutely tight under mechanical stress. We have vast constructional experience, the most modern calculation methods and high-quality welding work. Special attention is paid tocorrosion protection. Pretreatment of the surface is processed by phosphating pickling, contributes to corrosion protection, justlike multi-coating with preset drying times for each layer. On request, hot-dip galvanization provides for even better protectionTest labTesting are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformersa- Measurement of winding resistance .b- Measurement of voltage ratio and check of phase displacement.c- Measurement of short circuit impedance and load losses.d-Measurement of no-load losses and current .e-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .B - Type tests :The following tests shall be carried outa- Temperature rise testb- Lightning impulse testC - Special tests :a- Determination of noise level according to IEC 60551 .b- Oil leakage testc- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .d- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).Packaging and transportationCompany IntroductionSHENDA electric group is a manufacturer and wholesale company that manufactures good & high quality electric transformers from 2000. The company provides the customized products and OEM service. The factory own the 3 production base worldwide,2 in China and 1 in USA.We also own a transformer research institute with more than 30 electric engineers .Our Services1. Pre-Sale Service- Quick response: reply you within 8 hours, to save your time.- Professional solution: supply professional completed solution base on your technical requirements, to complete your technical plan.- Quoataion: submit a competive price within 2 days, to promote your business2. In Sale Service- Supplying stipulated completed drawings- Supplying manufacturing plan and processing photos- Making the test plan and book hotel for the witness person- Making good arrangement of the delivery and shipment3. Afer Sale Service- Supplying professional supervision and commissioning within 15 days- Training the workers- Providing 12 months waranty of quality and perforanceFAQ1,Q:Are you manufacturer? A:Yes, we are manufacturer. Our factory is in JiangShanCity, zhejiang Province.2,Q:What is your delivery time ? A:Depend on the type of transformer.3,Q:What is your payment term? A:30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.4,Q:Are your transformers supported for customization ? A:Yes, of course. We can design and produce accroding to the technical requirements and parameters of customers.5,Q:Do you offer guarantee for the products? A:Yes. Different transformers is different. We offer at least one year guarantee for all of our transformers.6,Q:Do you accept Factory Acceptance Test? A:Yes. It's available. And we are responsible for each set transformer's testing (ICE).7,Q:Do you assign engineer for after-sale service? A:Yes. For our products,we all provide after-sale installation instructions service