Product Name: Wld22000 OEM Bus&Truck Spray Baking Booth Oven Model NO.: WLD22000 Condition: New Paint Mist Treatment: Dry-type Heating Mode: Natural Gas Airflow Direction: Lateral Undershot-type Coating: Powder Coating Brand: Weilongda Substrate: Steel Certification: CCC, CE, GS Type: Spraying Painting Booth Internal Size: 22X6X5m Control System: Touch Screen, PLC, Convertor Trademark: WeiLongDa Transport Package: Export Standard Specification: Truck Bus Type Origin: Guangzhou, China HS Code: 84198990 Product Description This is a custom booth. We have many standard spray booth models and we can also make customized spray booth. Welcome to send inquiry to us.Project:22m×6m×5mConfigurationTechnical requirements1.Extraction from both side.2.All motors must be SIEMENS or WEG. All motors must be controlled with Variable Speed Drives/Frequency Inverters,made by Schenider only.3.The airflow velocities are at least 0.4m/s downdraft velocity,in an empty booth4.Entrance door with electrical rolling door5.Each booth requires a minimum of 4×Personal Doors.6.All ceiling filter frames must be hinged,to open from the side of the booth. All ceiling filter frames must be manfactured from stainless steel,and not the normal power coated steel.7.The required Lighting may be no less than 1000 Lux.8.All air control dampers must be automatic.9.The primacy intake filters must be pocket type filters.10.The Touch Screen with PLC is provided,and must be Schenider.11.All the viewing windows will be aluminum alloy frame,and cannot be opened.12.The glass of the viewing window is 8mm clear tempered glass.13.All the materials must be able to survive fire for 60 minutes.Wall panels to be insulated with rock wool or mineral.14.Air intake and exhaust fire proof damper and fire shutter must be equipped with fusible connetion.Where there is a sparks,fusible connection will be activated,thus close the fire shutter.The fire shutter must be electric,to be operated on the control box.15.The booth must be equipped with Differential Pressure M and temperature sensor,to ensure the pressure in the booth is monitered all the time,and the reminder of changing the filter.16.The booth must be equipped with alarm system,pressure gauge,differential pressure gaugeDimension of Room BodyInside Dimension22000×6000×5000(L×W×H)Outside Dimension22152×9750×5600(L×W×H)Air Collect CabinetDesign TypeQuadrate steel frame,at each side of room bodyFiter Area101 square metersRoom BodyStructureQuadrate steel support,dragon gate structure,panel vertical settingHeight of Plenum600mmWall panelRock wool 75mm,0.6mm color steel,snow whiteRoof PanelRock wool 75mm,0.6mm color steel,snow whiteEdge CoverGalvanzied steel bendingEntrance DoorsDoor TypeFloding type DoorsSize4000×4800mm(W×H)Quantity2units,entrance door,drive through typePersonal DoorDoor Typeframe StructureSize800×2000mm(W×H)Quantity2 units on each side,4 units in total,distance from the bottom of an open door to the ground to be 20 mm.DescriptionWith safe glass window,thickness:8mmCeiling LightsAll lights must be able to be changed from outside of the spray booth.Quantity and Power28units,4×36w/unit,4032w for total,Philips brandLayout2 rows,14 fitting on each side,total 28 fittingsSide lightsAll lights must be able to be changed from outside of the spray booth.Quantity and Power34 units,4×36w/unit,4896w for total,Philips brandLayout2 raws,on each side of room bodyThe 22 m Spray booth must have end wall lights, installed on the sides of the folding door, each side having 1x fitting,2 fittings for one door,total 16 pcs of tubes for two doorsIllumination>1000LuxFilter SystemPerforated deflector plates are to be installed on each inlet to the top plenum, as to ensure that even mixing of the air and laminar air flow through the ceiling filterPre-filterG3 bag filter,has large dust resistance capacity and high efficiency.inital resitance: 30Pa,final resitance:200Pa,100% wet resitanceCeiling filterF5 class filter,Model-SP-600G,has large dust resistance capacity and high efficiency.Thickness:22mm.Inital resistance:30Pa. Final resitance:450Pa.Temperatuere resistance:120°C,temperature short peaks:140°C.Max:temperature holding quantity: 650g/squre meterSide filterFiberglass filter: thickness:50/60mm,initial resitance:15Pa,final resitance:250Pa,temperature resitance:170°C,temperature short peaks: 190°C,max temperature holding quantity:3200-3600g/square meterExhaust filterF bag filter,initial resitance: 43Pa,final resistance: 250Pa,80% wet resistance,color: white,flame resitance: FADescription of ceiling filter frameStainless frame with hinges to change the filter easily.With defetor plateInlet SystemFan typeTurbo fanPower of fan and description of motor6×11KW,380V,50Hz,SIEMENS motorDate of inlet fan190080m³/hour,500PaHeating SystemMaterial of heating exchangerStainless 1Gr18Ni9Ti(SUS304)Power of heating exchanger6×440KWT temperature raising ability25°C(from -5°C to 20°C under painting)Max working temperature80°CTemperature raising time10-15min(from 20°to 60°C) under bakingModel of BurnerRS34/2 gas burnerThe air generation units must also be fitted with white insulated panels,extraction plenums must be from White Powder coated Mild Steel panels, and must be bolted panels.All panels which can be opened to access the fans, internal filters or other internal items, must be opened using knobs, not needing any tools.Heating recycle systemNoEach of the spray booths must be fitted with 4 x temperature probes, which will record the internal temperature of the spray booth, at different points.These readings must be made available on the Touch Screen PLC.Outlet SystemFan typeTurbo fanPower of fan and description of motor6×11KW,380V,50Hz,SIEMENS motorDate of outlet fan190080m³/hour,500PaFree Air Speed+/-0.4mm/freeNoise<75db(A) Add noise attenuation at the duct to reduce the noise. With sound insulation inside of fanDuctOutlet DuctSize1000×1000Straight Duct36pcsWater Proof Cap6pcsControl SystemAll electrical components and switchgear must be from Schneider,10" Shneider HMI Touch ScreenActuate StandardFunctionPainting,heating painting,flash,baking,SIEMENS PLC control,lighting switchSecure SystemOver temperature stop function,failure alarm,outset indicator,safe temperature lower stop,emergency stop,filter pressure alarm,fan and heating chain control,finger pressure monitor,Solenoid Valve and Pressure Adjustment Control Driven DamperThe system can indicate that when the fans are running and the doors are open,the alarm rings.Pressure Ajustment SystemOutlet electrical damperFire ProofFire damper for inlet,electrical damper for outletOther FacilitiesCE standard wire,wire box,pipeAdditionalAdditional 6m air duct for each air intak system to make it same as air exhaust ductadditional 5 m duct for all intakes and exhausts.2 x Additional Sets of replacement filters per spray booth.